Methods
The methods followed in the creation of the dataset, including description of field, laboratory and processing steps, and quality control procedures
Current Methods
Precipitation samples
Started: 1994-04-06Weekly collection of precipation for chemical analysis is performed at two different sites. Precipitation amount, pH and conductivity analysis is performed at the sites. The sample is shipped to the NADP Central Analytical Lab in Illinois for analysis of pH, conductivity, Ca, Mg, K, Na, NH4, NO3, Cl, SO4.
Ozone and deposition
Started: 1994-01-01Seasonal continuous ozone (May through September), averaged hourly. Deposition (kg/ha) was calculated for chemicals reporting concentration in mg/l for annual, seasonal and montly time steps.
Meteorological data
Started: 1994-01-01Continuous meteorology averaged hourly includes ambient temperature at 2 and 10 m height, relative humidity, surface wetness, precipitation, wind speed and direction, solar radiation.
Past Methods (No longer in use)
- Sample analysis
Started: 1995-07-04
Ended: 1999-02-02Accumulated weekly samples; analysis includes SO2, HNO3, pH, conductivity, acidity and major ions.
Dataset Fields
Detailed documentation of the fields comprising the dataset, including the type of measurement, units where applicable, and any controlled vocabularies or code lists present in the data
Field Name Caption Description Additional Information Site I.D. Site Identification Unique site identifier
Measurement type: Nominal Date Time Date and time Date and time measurements were recorded
Measurement type: DateTime
Date/Time Format: YYYY-MM-DD hh:mm:ssOzone Ozone ppb Ozone concentration measured in parts per billion
Measurement type: Ratio
Units: dimensionless
Precision: 1Ozone flag Ozone Data Flagged Data flagged with quality control code
Measurement type: Ordinal
Ozone Flag Class
+ showAppears in data as Meaning of code I Not Valid M Missing Data B No sample (all data loggeres), channel downed by operator (CR3000 collected data) N Valid with no Conditions Ozone 8 hour 8 hour average Average ozone concentration measured in 8 hours
Measurement type: Ratio
Units: dimensionless
Precision: 2Rank Unknown Unkown
Measurement type: Nominal Sampling Equipment
Equipment and software used to collect data, including how that equipment was used.
No sampling equipment recorded for this dataset
Site Characteristics
The spatial extent of the dataset site coverage, and descriptions of the spatial extent and context for the data collection
- Site Description
Green Mountain National Forest, Stratton, just south of the Lye Brook Wilderness Area boundary. Summit of hill with southwest airflow.