Details and Metadata
Printer-friendly version View XML version Download Ecological Metadata Language file
Methods
The methods followed in the creation of the dataset, including description of field, laboratory and processing steps, and quality control procedures
Current Methods
Data collection
Started: 1998-07-24Automated station replaced previous equipment to allow for continuous data collection with 15 minute averages,remote QA checks and weekly automated access, 7/24/1998.
Process data
Started: 1988-06-01Hourly and daily averages computed.
Measurements
Started: 1988-06-01Measurements include ambient air temperature; wind speed, direction and direction variance; relative humidity; precipitation; barometric pressure.
Past Methods (No longer in use)
- Data collection
Started: 1988-06-01
Ended: 1998-07-23Continuous measurements on 10m tower, averaged hourly. Time is displayed as Greenwich mean time.
Dataset Fields
Detailed documentation of the fields comprising the dataset, including the type of measurement, units where applicable, and any controlled vocabularies or code lists present in the data
Field Name Caption Description Additional Information TIMESTAMP Date and Time Date and time data were recorded
Measurement type: DateTime
Date/Time Format: YYYY-MM-DD hh:mm:ssRECORD Record Number Unique Record Identifyer
Measurement type: Ordinal GageMinV Raingauge Minimum Voltage Minimum voltage of raingauge battery
Measurement type: Ratio
Unit: unavailable
Precision: 0.01ActTemp Actual Temperature Temperature recorded at raingauge data logger
Measurement type: Interval
Unit: unavailable
Precision: 0.01ActDepth Actual Depth Actual raingauge bucket depth
Measurement type: Ratio
Unit: unavailable
Precision: 0.000001ReportPCP Report Precipitation Precipitation sensed and measured
Measurement type: Ratio
Unit: unavailable
Precision: 0.01collMinVolt_1 Collector 1 Minimum Voltage Minimum voltage of precipitation collector 1
Measurement type: Ratio
Unit: unavailable
Precision: 0.01Cycles_1 Lid cycles Collector 1 lid cycles
Measurement type: Ratio
Units: dimensionless
Precision: 1WetTime_1 Seconds of Wet Exposure Number of seconds collector 1 Is open during precipitation
Measurement type: Ratio
Unit: unavailable
Precision: 1DryTime_1 Seconds of Dry Exposure Number of seconds collector 1 Is open when there is no precipitation
Measurement type: Ratio
Unit: unavailable
Precision: 1MissedTime_1 Seconds of Missed Exposure Number of seconds collector 1 should have opened but did not
Measurement type: Ratio
Unit: unavailable
Precision: 1collMinVolt_2 Collector 2 Minimum Voltage Minimum voltage of precipitation collector 2
Measurement type: Ratio
Unit: unavailable
Precision: 0.01Cycles_2 Lid cycles Collector 2 lid cycles
Measurement type: Ratio
Units: dimensionless
Precision: 1WetTime_2 Seconds of Wet Exposure Number of seconds collector 2 Is open during precipitation
Measurement type: Ratio
Unit: unavailable
Precision: 1DryTime_2 Seconds of Dry Exposure Number of seconds collector 2 Is open when there is no precipitation
Measurement type: Ratio
Unit: unavailable
Precision: 1MissedTime_2 Seconds of Missed Exposure Number of seconds collector 2 should have opened but did not
Measurement type: Ratio
Unit: unavailable
Precision: 1collMinVolt_3 Collector 3 Minimum Voltage Minimum voltage of precipitation collector 2
Measurement type: Ratio
Unit: unavailable
Precision: 0.01Cycles_3 Lid cycles Collector 3 lid cycles
Measurement type: Ratio
Units: dimensionless
Precision: 1WetTime_3 Seconds of Wet Exposure Number of seconds collector 3 Is open during precipitation
Measurement type: Ratio
Unit: unavailable
Precision: 1DryTime_3 Seconds of Dry Exposure Number of seconds collector 3 Is open when there is no precipitation
Measurement type: Ratio
Unit: unavailable
Precision: 1MissedTime_3 Seconds of Missed Exposure Number of seconds collector 3 should have opened but did not
Measurement type: Ratio
Unit: unavailable
Precision: 1blockedSec Blocked Sensors Number of seconds optical sensors are blocked
Measurement type: Ratio
Unit: unavailable
Precision: 1ActDepthRA Actual Depth Running Average Running average of actual raingauge bucket depth
Measurement type: Ratio
Unit: unavailable
Precision: 0.000001Sampling Equipment
Equipment and software used to collect data, including how that equipment was used.
Current Equipment
Weather sensors, datalogger
Started: 1988-06-01Automated weather sensors mounted on a 10 m tower with a Campbell CR10X datalogger.
Rain gauge
Started: 2013-06-09NOAH IV rain gauge
Site Characteristics
The spatial extent of the dataset site coverage, and descriptions of the spatial extent and context for the data collection
- Site Description
West slope of Mount Mansfield in an open field at the Proctor Maple Research Center. Site has a west aspect and an 8% slope.
Dataset Notes
Notes describing any special conditions or considerations for understanding the quality and consistency of the data
Start Date End Date Note Date Entered 2015-09-29 15:45:00 2015-09-29 15:45:00 Erroneous precipitation value recorded, ReportPCP set to null for this time 2015-10-19 00:00:00 2015-09-29 15:15:00 2015-09-29 15:15:00 Erroneous precipitation value recorded, ReportPCP set to null for this time 2015-10-19 00:00:00 2015-09-15 14:30:00 2015-09-22 00:00:00 Rain gauge collector bucket was not seated properly during this interval, leading to improper precipitation readings. ActDepth, ReportPCP and ActDepthRA set to null for the period. 2015-10-19 00:00:00