Details and Metadata
Printer-friendly version View XML version Download Ecological Metadata Language file
Methods
The methods followed in the creation of the dataset, including description of field, laboratory and processing steps, and quality control procedures
Current Methods
Particulate matter monitoring
Started: 1988-09-01Particulate matter is being monitored at the PMRC for fine particles <2.5 microns (PM-2.5), using the IMPROVE sampler, is sampled Wednesday & Saturday for mass, and elemental composition (H, Na-Pb).
Particulate matter is being monitored at the PMRC for fine particles <2.5 microns (PM-2.5), using the IMPROVE sampler, is sampled every third day for mass, optical absorption and elemental composition (H, Na-Pb).
Dataset Fields
Detailed documentation of the fields comprising the dataset, including the type of measurement, units where applicable, and any controlled vocabularies or code lists present in the data
Field Name Caption Description Additional Information Bromine Bromine Bromine Conc.
Measurement type: Ratio
Units:Br_DL/2 Br_DL/2 Br_DL/2
Measurement type: Ratio
Units:Date Date Date
Measurement type: DateTime
Date/Time Format: DD/MM/YYYYKnon Knon Knon conc.
Measurement type: Ratio
Units:Knon_DL/2 Knon_DL/2 Knon_DL/2
Measurement type: Ratio
Units:Lead Lead Lead
Measurement type: Ratio
Units:Locat Location Location
Measurement type: Ratio
Units:Na_DL/2 Na_DL/2 Na_DL/2
Measurement type: Ratio
Units:Pb_DL/2 Pb_DL/2 Pb_DL/2
Measurement type: Ratio
Units:Sodium Sodium Sodium
Measurement type: Ratio
Units:Zinc Zinc Zinc
Measurement type: Ratio
Units:Zn_DL/2 Zn_DL/2 Zn_DL/2
Measurement type: Ratio
Units:Sampling Equipment
Equipment and software used to collect data, including how that equipment was used.
Current Equipment
Aerosol sampler
IMPROVE Module A Sampler
Duplicate sampler
Duplicate sampler for precision purposes.
Site Characteristics
The spatial extent of the dataset site coverage, and descriptions of the spatial extent and context for the data collection
- Site Description
Field Station at Proctor Maple Research Center, west slope of Mount Mansfield, establish in September 1988 as part of NESCAUM network.
- Site Description
Consistent with US EPA PM-2.5 Siting Criteria.
- Site Description
Field station for Lye Brook located on Little Equinox. Sampling there ended in October, 2012.
Minimum Altitude: 944 meter
Maximum Altitude: 944 meter
- Site Description
Field station for Lye Brook moved to Mount Snow, sampling began in December, 2011.
Minimum Altitude: 1006 meter
Maximum Altitude: 1006 meter