Details and Metadata
Printer-friendly version View XML version Download Ecological Metadata Language file
Methods
The methods followed in the creation of the dataset, including description of field, laboratory and processing steps, and quality control procedures
Current Methods
Started: 1992-12-15Year-round daily wet-only precipitation sampling, every sixth day aerosol and vapor phase sampling (24 hour sample). Measurements include: total Hg in precipitation, vapor and particulate phases, 24 other trace elements.
Vapor phase sampling ended in September 2001.
Past Methods (No longer in use)
Started: 1995-01-01
Ended: 2001-12-3124-hour sample of air collected every 6th day to measure vapor phase levels of mercury
Started: 1992-12-15
Ended: 1994-10-0524-hour sample of air collected every Wednesday and every 6th day to measure vapor phase levels of mercury
Instrumentation: Gold-coated sand vapor traps
Started: 1992-12-15
Ended: 1995-02-04Samples shipped to University of Michigan Air Quality Lab for analysis by cold vapor atomic fluorescence spectrometry
Dataset Fields
Detailed documentation of the fields comprising the dataset, including the type of measurement, units where applicable, and any controlled vocabularies or code lists present in the data
Field Name Caption Description Additional Information Batch Batch ID Batch group ID
Measurement type: Nominal DateOn Date Trap Put On Date that the gold trap was put out for sampling
Measurement type: DateTime
Date/Time Format: YYYY-MM-DDTimeOn Time Trap Put On Time the gold trap was put out to sample
Measurement type: DateTime
Date/Time Format: hh:mmsite Site Code Site code
Measurement type: Nominal samplenumber Sample Number Sample Number
Measurement type: Ordinal samplevolume Sample Volume Volume of the sample collected
Measurement type: Ratio
Units:STPcorrected_sampVol Corrected Sample Volume Volume of the sample corrected to standard temperature and pressure (1013.25mb at 25C)
Measurement type: Ratio
Units:VolumeUnits Volume Units Units used for reporting volume
Measurement type: Nominal Duration_min Sample Duration Duration of sampling
Measurement type: Ratio
Unit: unavailable
Precision: 1Blank Blank Mercury Concentration Mercury found on the field blank
Measurement type: Ratio
Units:STP_corrected_Result Mercury Concentration (Corrected) Concentration of mercury, corrected to standard temperature and pressure (1013.25mb at 25C)
Measurement type: Ratio
Units:Unit Units Units used to report concentrations
Measurement type: Nominal NonSTPcorrectedResult Mercury Concentration (Corrected) Concentration of mercury, not corrected
Measurement type: Ratio
Units:Sampling Equipment
Equipment and software used to collect data, including how that equipment was used.
Past Sampling Equipment (No longer in use)
Trap
Started: 1992-12-16
Ended: 2006-08-27Gold plated glass bead trap
Site Characteristics
The spatial extent of the dataset site coverage, and descriptions of the spatial extent and context for the data collection
- Site Description
West slope of Mount Mansfield at the Proctor Maple Research Center.