Details and Metadata
Printer-friendly version View XML version Download Ecological Metadata Language file
Methods
The methods followed in the creation of the dataset, including description of field, laboratory and processing steps, and quality control procedures
Current Methods
Started: 1992-12-15Year-round daily wet-only precipitation sampling, every sixth day aerosol and vapor phase sampling (24 hour sample). Measurements include: total Hg in precipitation, vapor and particulate phases, 24 other trace elements.
Past Methods (No longer in use)
- Precipitation samples
Started: 1992-12-15
Ended: 2006-07-01Precipitation samples collected every morning following precipitation
Dataset Fields
Detailed documentation of the fields comprising the dataset, including the type of measurement, units where applicable, and any controlled vocabularies or code lists present in the data
Field Name Caption Description Additional Information Batch Batch Batch identifier
Measurement type: Nominal DateOn Date On Date the sample train was put in
Measurement type: DateTime
Date/Time Format:Study Study code Study code
Measurement type: Nominal Site Site Site code
Measurement type: Nominal samplenumber Sample Number Sample number
Measurement type: Ordinal tag1 Tag 1 Unknown
Measurement type: Nominal tag2 Tag 2 Unknown
Measurement type: Nominal type Type Type
Measurement type: Nominal N N Unknown
Measurement type: Nominal analyticalVolume_ml Analytical Volume Volume of analytical sample
Measurement type: Ratio
Unit: unavailable
Precision: 1BlankConc_Ng_L Field Blank Concentration Concentration of mercury on the field blank
Measurement type: Ratio
Unit: unavailable
Precision: 0.001DetectionLimit_Ng Detection Limit Limit of detection for mercury
Measurement type: Ratio
Unit: unavailable
Precision: 0.000000001Result Resulting Concentration Concentration of mercury after analysis
Measurement type: Ratio
Units:ResultUnits Resulting Concentration Units Units used in reporting the final concentration
Measurement type: Nominal PrecipAmnt_cm Precipitation amount Amount of precipitation yielding sample
Measurement type: Ratio
Unit: unavailable
Precision: 0.001Deposition_ug_m2 Mercury Deposition Amount Amount of mercury deposited in sample
Measurement type: Ratio
Unit: unavailable
Precision: 0.001Sampling Equipment
Equipment and software used to collect data, including how that equipment was used.
Past Sampling Equipment (No longer in use)
Precipitaton Collector
Started: 1992-12-15
Ended: 2006-12-31MIC-B wet only precipitation collector
Site Characteristics
The spatial extent of the dataset site coverage, and descriptions of the spatial extent and context for the data collection
- Site Description
West slope of Mount Mansfield at the Proctor Maple Research Center.