Campbell Scientific Weather Station
Started: 2017-08-03Hourly measurements of weather variables taken at Teatown Lake Reservation. Note that TIMESTAMP represents the DateTime for the previous hour.
Dataset Fields
Detailed documentation of the fields comprising the dataset, including the type of measurement, units where applicable, and any controlled vocabularies or code lists present in the data
Field Name Caption Description Additional Information AirT_Max AirT_Max Maximum Air Temperature
Measurement type: Ratio
Units: deg C
Precision: 0.001AirT_Mean AirT_Mean Mean Air Temperature
Measurement type: Ratio
Units: deg C
Precision: 0.001AirT_Min AirT_Min Minimum Air Temperature
Measurement type: Ratio
Units: deg C
Precision: 0.001AirT_TMax AirT_TMax Time of Maximum Air Temperature
Measurement type: DateTime
Date/Time Format: M/D/YYYY hh:mmAirT_TMin AirT_TMin Time of Minimum Air Temperature
Measurement type: DateTime
Date/Time Format: M/D/YYYY hh:mmBattV_Min BattV_Min Minimum Battery Voltage
Measurement type: Ratio
Units: volts
Precision: 0.001CS655T10Mean CS655T10Mean Mean soil temperature at 10 cm depth, as measured by the CS655 moisture probe.
Measurement type: Ratio
Units: deg C
Precision: 0.001DewPt_Max DewPt_Max Maximum Dewpoint Temperature
Measurement type: Ratio
Units: deg C
Precision: 0.001DewPt_Mean DewPt_Mean Mean Dewpoint Temperature
Measurement type: Ratio
Units: deg C
Precision: 0.001DewPt_Min DewPt_Min Minimum Dewpoint Temperature
Measurement type: Ratio
Units: deg C
Precision: 0.001DewPt_TMax DewPt_TMax Time of Maximum Dewpoint Temperature
Measurement type: DateTime
Date/Time Format: M/D/YYYY hh:mmDewPt_TMin DewPt_TMin Time of Minimum Dewpoint Temperature
Measurement type: DateTime
Date/Time Format: M/D/YYYY hh:mmHeatInd_Max HeatInd_Max Maximum Heat Index
Measurement type: Ratio
Units: deg C
Precision: 0.001HeatInd_Mean HeatInd_Mean Mean Heat Index
Measurement type: Ratio
Units: deg C
Precision: 0.001HeatInd_TMax HeatInd_TMax Time of Maximum Heat Index
Measurement type: DateTime
Date/Time Format: M/D/YYYY hh:mmPrecip Precip Total Precipitation
Measurement type: Ratio
Units: mm
Precision: 0.001RECORD RECORD Record Number
Measurement type: Ratio
Units: unitless
Precision: 1RH_Max RH_Max Maximum Relative Humidity
Measurement type: Ratio
Units: percent
Precision: 0.001RH_Mean RH_Mean Mean Relative Humidity
Measurement type: Ratio
Units: percent
Precision: 0.001RH_Min RH_Min Minimum Relative Humidity
Measurement type: Ratio
Units: percent
Precision: 0.001RH_TMax RH_TMax Time of Maximum Relative Humidity
Measurement type: DateTime
Date/Time Format: M/D/YYYY hh:mmRH_TMin RH_TMin Time of Minimum Relative Humidity
Measurement type: DateTime
Date/Time Format: M/D/YYYY hh:mmSoilEC_Mean SoilEC_Mean Mean Soil Electrical Conductivity
Measurement type: Ratio
Units: dS/m
Precision: 0.001SoilT10_Mean SoilT10_Mean Mean Soil Temperature of Sensor at 10 cm depth
Measurement type: Ratio
Units: deg C
Precision: 0.001SoilT20_Mean SoilT20_Mean Mean Soil Temperature of Sensor at 20 cm depth
Measurement type: Ratio
Units: deg C
Precision: 0.001SoilT5_Mean SoilT5_Mean Mean Soil Temperature of Sensor at 5 cm depth
Measurement type: Ratio
Units: deg C
Precision: 0.001SoilVWC_Mean SoilVWC_Mean Mean Soil Volumetric Water Content
Measurement type: Ratio
Units: m^3/m^3
Precision: 0.001SolRad_Max SolRad_Max Maximum Solar Radiation
Measurement type: Ratio
Units: kW/m^2
Precision: 0.001SolRad_Mean SolRad_Mean Mean Solar Radiation
Measurement type: Ratio
Units: kW/m^2
Precision: 0.001SolRad_Min SolRad_Min Minimum Solar Radiation
Measurement type: Ratio
Units: kW/m^2
Precision: 0.001SolRad_SD SolRad_SD Standard Deviation of Solar Radiation
Measurement type: Ratio
Units: kW/m^2
Precision: 0.001SolRad_Tot SolRad_Tot Total Solar Radiation
Measurement type: Ratio
Units: MJ/m^2
Precision: 0.000000001SunHrs_Tot SunHrs_Tot Total Number of Hours of Sun
Measurement type: Ratio
Units: hours
Precision: 10TIMESTAMP TIMESTAMP DateTime for previous hour
Measurement type: DateTime
Date/Time Format: M/D/YYYY hh:mmSampling Equipment
Equipment and software used to collect data, including how that equipment was used.
Current Equipment
Air Temperature
Started: 2017-08-03Rotronic, Model HC2S3-10-PT. Rotronic HygroClip2 Temperature/RH Probe. Temp: ±0.1°C with standard configuration settings (at 23°C). Humidity: ±0.8% RH with standard configuration settings (at 23°C)
Frequency: hourly
Campbell Scientific Datalogger
Started: 2017-08-03Campbell Scientific, Model CR6-NA-ST-SW
Frequency: hourly
Global short wave radiation accessory
Started: 2017-08-03Campbell Scientific, Model 18356. Leveling base for pyranometer.
Frequency: hourly
Global shortwave radiation
Started: 2017-08-03Apogee, Model SP230-L12-PT. All-season heated pyranometer. Accuracy ±5% for daily total radiation
Frequency: hourly
Global shortwave radiation accessory
Started: 2017-08-03Campbell Scientific, Model CM225. Mounting stand for pyranometer.
Frequency: hourly
Precipitation accessory
Started: 2017-08-03Novalynx, Model 260-953. Alter-type rain gauge wind screen, 36" legs
Frequency: hourly
Precipitation gauge
Started: 2017-08-03RM Young, Model 52202-L17-LP13. Heated rain and snow gauge, 0.1mm resolution. Accuracy 2% up to 25 mm h-1 (1 in. h-1) 3% up to 50 mm h-1 (2 in. h-1)
Frequency: hourly
Relative humidity
Started: 2017-08-03Rotronic, Model HC2S3-10-PT. Rotronic HygroClip2 Temperature/RH Probe. Temp: ±0.1°C with standard configuration settings (at 23°C). Humidity: ±0.8% RH with standard configuration settings (at 23°C)
Frequency: hourly
Shield for temperature/relative humidity sensor
Started: 2017-08-03RM Young, Model 41003-5. 10-plate radiation shield
Frequency: hourly
Soil moisture & electrical conductivity
Started: 2017-08-03Campbell Scientific, Model CS655-17-PT-DS. Soil water content reflectometer (also measures conductivity and temperaure). Readings represent an average of conditions along 12 cm length of rods. Volumtric water content: range 5% to 50%, accuracy ±3% VWC (typical in mineral soils that have solution electrical conductivity ≤ 10 dS/m), precision < 0.05%. Temperature: range -10° to +70°C, acc ±0.5°C, prec ±0.02°C. Conductivity: range for Bulk EC 0 to 8 dS/m, acc ±(5% of reading + 0.05 dS/m), prec 0.5% of BEC.
Frequency: hourly
Soil temperature at 5, 10 & 20 cm
Started: 2017-08-03Campbell Scientific, Model 105E-L13. Type E Thermocouple Burial Probe
Frequency: hourly