Details and Metadata
Printer-friendly version View XML version Download Ecological Metadata Language file
Methods
The methods followed in the creation of the dataset, including description of field, laboratory and processing steps, and quality control procedures
Current Methods
- Mohonk Meteorological Data- This dataset is part of the Mohonk Preserve Environmental Monitoring Program, a long-term research program designed to monitor climate change, air, precipitation and streamwater chemistry, solar radiation, stream flow and temperature, soil moisture and soil temperature. - Datalogger- Campbell Scientific, Model CR6-NA-ST-SW. - Dataset Fields- Detailed documentation of the fields comprising the dataset, including the type of measurement, units where applicable, and any controlled vocabularies or code lists present in the data 
 - No documentation available for these fields - Sampling Equipment- Equipment and software used to collect data, including how that equipment was used. - Current Equipment- Air temperature- Rotronic, Model HC2S3-10-PT. Rotronic HygroClip2 Temperature/RH Probe. Temp: ±0.1°C with standard configuration settings (at 23°C). Humidity: ±0.8% RH with standard configuration settings (at 23°C) 
- Global short wave radiation- Apogee, Model SP230-L12-PT. All-season heated pyranometer. Accuracy ±5% for daily total radiation 
- Global short wave radiation accessory- Campbell Scientific, Model 18356. Leveling base for pyranometer. 
- Global short wave radiation accessory- Campbell Scientific, Model CM225. Mounting stand for pyranometer. 
- Precipitation accessory- Novalynx, Model 260-953. Alter-type rain gauge wind screen, 36" legs 
- Precipitation gauge- RM Young, Model 52202-L17-LP13. Heated rain and snow gauge, 0.1mm resolution. Accuracy 2% up to 25 mm h-1 (1 in. h-1) 3% up to 50 mm h-1 (2 in. h-1) 
- Relative humidity- Rotronic, Model HC2S3-10-PT. Rotronic HygroClip2 Temperature/RH Probe. Temp: ±0.1°C with standard configuration settings (at 23°C). Humidity: ±0.8% RH with standard configuration settings (at 23°C) 
- Shield for temperature/relative humidity sensor- RM Young, Model 41003-5. 10-plate radiation shield 
- Soil moisture & electrical conductivity- Campbell Scientific, Model CS655-17-PT-DS. Soil water content reflectometer (also measures conductivity and temperaure). Readings represent an average of conditions along 12 cm length of rods. Volumtric water content: range 5% to 50%, accuracy ±3% VWC (typical in mineral soils that have solution electrical conductivity ≤ 10 dS/m), precision < 0.05%. Temperature: range -10° to +70°C, acc ±0.5°C, prec ±0.02°C. Conductivity: range for Bulk EC 0 to 8 dS/m, acc ±(5% of reading + 0.05 dS/m), prec 0.5% of BEC. 
- Soil temperature at 10cm- Campbell Scientific, Model 105E-L13. Type E Thermocouple Burial Probe 
- Soil temperature at 20cm- Campbell Scientific, Model 105E-L13. Type E Thermocouple Burial Probe 
- Soil temperature at 5cm- Campbell Scientific, Model 105E-L13. Type E Thermocouple Burial Probe 
 - Site Characteristics- The spatial extent of the dataset site coverage, and descriptions of the spatial extent and context for the data collection - Site DescriptionThe Mohonk Preserve Smiley House weather station is in a small field near the Daniel Smiley Research Center at the Mohonk Preserve. GPS coordinates for the site are 41.7681, -74.155. Minimum Altitude: 1124 feet Maximum Altitude: 1125 feet 
 

 
     
     Details