Details and Metadata
Printer-friendly version View XML version Download Ecological Metadata Language file
Methods
The methods followed in the creation of the dataset, including description of field, laboratory and processing steps, and quality control procedures
Current Methods
Mohonk Meteorological Data
This dataset is part of the Mohonk Preserve Environmental Monitoring Program, a long-term research program designed to monitor climate change, air, precipitation and streamwater chemistry, solar radiation, stream flow and temperature, soil moisture and soil temperature.
Datalogger
Campbell Scientific, Model CR6-NA-ST-SW.
Dataset Fields
Detailed documentation of the fields comprising the dataset, including the type of measurement, units where applicable, and any controlled vocabularies or code lists present in the data
No documentation available for these fields
Sampling Equipment
Equipment and software used to collect data, including how that equipment was used.
Current Equipment
Air temperature
Rotronic, Model HC2S3-10-PT. Rotronic HygroClip2 Temperature/RH Probe. Temp: ±0.1°C with standard configuration settings (at 23°C). Humidity: ±0.8% RH with standard configuration settings (at 23°C)
Global short wave radiation
Apogee, Model SP230-L12-PT. All-season heated pyranometer. Accuracy ±5% for daily total radiation
Global short wave radiation accessory
Campbell Scientific, Model 18356. Leveling base for pyranometer.
Global short wave radiation accessory
Campbell Scientific, Model CM225. Mounting stand for pyranometer.
Precipitation accessory
Novalynx, Model 260-953. Alter-type rain gauge wind screen, 36" legs
Precipitation gauge
RM Young, Model 52202-L17-LP13. Heated rain and snow gauge, 0.1mm resolution. Accuracy 2% up to 25 mm h-1 (1 in. h-1) 3% up to 50 mm h-1 (2 in. h-1)
Relative humidity
Rotronic, Model HC2S3-10-PT. Rotronic HygroClip2 Temperature/RH Probe. Temp: ±0.1°C with standard configuration settings (at 23°C). Humidity: ±0.8% RH with standard configuration settings (at 23°C)
Shield for temperature/relative humidity sensor
RM Young, Model 41003-5. 10-plate radiation shield
Soil moisture & electrical conductivity
Campbell Scientific, Model CS655-17-PT-DS. Soil water content reflectometer (also measures conductivity and temperaure). Readings represent an average of conditions along 12 cm length of rods. Volumtric water content: range 5% to 50%, accuracy ±3% VWC (typical in mineral soils that have solution electrical conductivity ≤ 10 dS/m), precision < 0.05%. Temperature: range -10° to +70°C, acc ±0.5°C, prec ±0.02°C. Conductivity: range for Bulk EC 0 to 8 dS/m, acc ±(5% of reading + 0.05 dS/m), prec 0.5% of BEC.
Soil temperature at 10cm
Campbell Scientific, Model 105E-L13. Type E Thermocouple Burial Probe
Soil temperature at 20cm
Campbell Scientific, Model 105E-L13. Type E Thermocouple Burial Probe
Soil temperature at 5cm
Campbell Scientific, Model 105E-L13. Type E Thermocouple Burial Probe
Site Characteristics
The spatial extent of the dataset site coverage, and descriptions of the spatial extent and context for the data collection
- Site Description
The Mohonk Preserve Smiley House weather station is in a small field near the Daniel Smiley Research Center at the Mohonk Preserve. GPS coordinates for the site are 41.7681, -74.155.
Minimum Altitude: 1124 feet
Maximum Altitude: 1125 feet