Details and Metadata
Printer-friendly version View XML version Download Ecological Metadata Language file
Methods
The methods followed in the creation of the dataset, including description of field, laboratory and processing steps, and quality control procedures
Current Methods
Meteorology data
Started: 1999-07-26This Mount Mansfield station provides basic meteorological variables including wind speed and direction, air temperature, relative humidity, total solar irradiance, photosynthetically active radiation (PAR), and precipitation during non-freezing months. Data are stored as 15 minute averages to a data storage module changed every 57 days or less. The station is located within a mixed aspen-birch spruce-fir forest, and represents mid-elevation forest meteorology.
Dataset Fields
Detailed documentation of the fields comprising the dataset, including the type of measurement, units where applicable, and any controlled vocabularies or code lists present in the data
Field Name Caption Description Additional Information RECORDTIME Record Time Time and date of collection
Measurement type: DateTime
Date/Time Format: YYYY-MM-DD hh:mm:ssSAMPLEYEAR Year Sampled Year of sample
Measurement type: DateTime
Date/Time Format: otherSAMPLEDAY Day Sampled Day of year of collection
Measurement type: DateTime
Date/Time Format: otherSAMPLETIME Time of Sample Time of collection
Measurement type: DateTime
Date/Time Format: otherMAX_WINDSPEED Max Windspeed Maximum windspeed
Measurement type: Ratio
Unit: unavailable
Precision: 0.001TIME_MAX_WINDSPEED Time of Maximum Windspeed Time of maximum measured windspeed
Measurement type: DateTime
Date/Time Format: otherMEAN_HORIZONTAL_WINDSPEED Mean Horizontal Windspeed Mean horizontal windspeed
Measurement type: Ratio
Unit: unavailable
Precision: 0.001MEAN_RESULTANT_WINDSPEED Mean Resultant Windspeed Mean resultant windspeed
Measurement type: Ratio
Unit: unavailable
Precision: 0.001MEAN_WIND_DIRECTION Mean Wind Direction Mean wind direction
Measurement type: Ratio
Unit: unavailable
Precision: 0.1STDDEV_WIND_DIRECTION Standard Deviation Wind Direction Standard deviation of wind direction
Measurement type: Ratio
Unit: unavailable
Precision: 0.01AIRTEMP Air Temperature Measured air temperature
Measurement type: Ratio
Unit: unavailable
Precision: 0.01RELHUMID Relative Humidity Relative Humidity
Measurement type: Ratio
Units: dimensionless
Precision: 0.1PRECIP Precipitation Total precipitation
Measurement type: Ratio
Unit: unavailable
Precision: 0.1PYRANOM Pyranomater Reading Pyranometer reading of solar intensity
Measurement type: Ratio
Unit: unavailable
Precision: 1QUANTUM Quantum Quantum measurment
Measurement type: Ratio
Unit: unavailable
Precision: 1SAMPLEMONTH Sample Month Sample month of data collection
Measurement type: DateTime
Date/Time Format: otherSampling Equipment
Equipment and software used to collect data, including how that equipment was used.
Current Equipment
Data logger, weather sensors
Started: 1999-07-26Campbell CR10X data logger and storage module with automated weather sensors mounted on a 3 m tower.
Rain gauge
Started: 2001-09-06Unheated tipping bucket (rain gauge) installed in September 2001.
Site Characteristics
The spatial extent of the dataset site coverage, and descriptions of the spatial extent and context for the data collection
- Site Description
Station is located within the Ranch Valley watershed on the east slope of Mount Mansfield, about 200 feet from the auto-toll road in a small opening in spruce/fir forest. Approximate coordinates: 44.5194 N, 72.7988 W. Approximate elevation: 2878 feet.
Dataset Notes
Notes describing any special conditions or considerations for understanding the quality and consistency of the data
Start Date End Date Note Date Entered 2012-11-01 00:00:00 2013-04-15 23:59:00 Rain gauge closed for the season. Precipitation data values set to NULL. 2013-10-23 15:31:00 2012-08-27 09:30:00 2012-08-27 10:00:00 cleared site with loppers and saw. cleaned rain guage. Replaced temperature/humidity probe for calibration purposes. restrung raingauge guide wires. 2012-08-28 00:00:00 2012-07-05 09:00:00 2012-07-05 09:30:00 cleaned rain gauge at 9:40. precip data needs to be nullifed 2012-07-06 13:00:00 2012-06-19 09:40:00 2012-06-19 09:45:00 cleaned rain gauge at 9:40. precip data needs to be nullifed 2012-06-20 00:00:00 2012-05-23 10:00:00 2012-05-23 10:00:00 rain gauge opend for the season on May 23, 2012 (doy 144) at 10:00 am EST. 2012-05-23 10:00:00 2011-10-02 21:30:00 2011-10-16 12:00:00 Rain gauge cloged from 10/2/11 @ 21:30 until 10/16/11 at 12:00 when the gauge was closed for the season. 2011-10-02 02:13:00 2011-06-06 11:00:00 2011-06-06 11:00:00 Rain Gauge opened for the season. Other instruments were untouched, however jostling of the tower may have occured. 2011-06-06 00:00:00 2010-10-10 10:30:00 2010-10-10 10:30:00 Rain Gauge covered and closed for the season 2010-10-10 10:30:00 2010-09-14 21:15:00 2010-10-09 10:30:00 Rain gauge clogged rendering data invalid, precip data deleted 2010-09-14 09:15:00 2009-10-07 17:45:00 0000-00-00 00:00:00 Pending. rain gauge closed for the season at 9:00 am EST rain gauge was clogged - precipitation data was nullified from 17:45 EST on 10-7-09 to and including 9:00 am EST on 10-8-09 changed data storage module changed desiccant change RM Young anemometer nose cone assembly all instruments visually inspected and instantaneous data values checked. 2010-05-13 13:24:00 2009-08-14 00:00:00 2009-08-14 00:00:00 air temperature/relative humidity probe changed for calibration purposes rain gauge checked - not clogged all instruments visually inspected and instantaneous data values checked changed data storage module changed desiccant. 2010-05-13 13:30:00 2008-10-07 00:00:00 2009-06-02 08:45:00 Rain Gauge Closed For Winter 2009-07-09 10:14:00 2007-10-16 00:08:00 2008-06-03 00:00:00 Rain gage closed for the winter 2008-01-17 16:27:00 2007-09-17 09:00:00 2007-09-17 10:00:00 Changed anemometer prop; and air temperature/relative humidity probe for calibration purposesd 2008-03-06 12:42:00 2007-08-27 14:15:00 2007-08-27 14:30:00 Rain gage cleaned; 1 false tip 2008-03-06 12:12:00 2006-10-10 12:00:00 2007-06-07 10:00:00 7 June 2007, discovered that 1 blade on the anemometer was missing but was unable to ascertain the date on which the damage occurred by examining the WS data 2008-03-06 12:15:00 2006-10-10 10:00:00 2007-06-07 10:00:00 Rain gage covered for winter 2007-06-12 13:22:00 2006-09-18 12:00:00 2006-09-18 12:00:00 Changed 12V battery and air temperature/relative humidity probe for calibration purposes; rain gage found clogged and was cleared 2008-03-06 12:41:00 2006-06-29 19:45:00 2006-09-18 10:30:00 Rain gage clogged; data for this time period nullified 2008-03-06 12:07:00 2005-10-21 10:15:00 2006-06-05 00:45:00 Rain gage closed for season, 10/21/05 at 10:15 EST 2007-02-23 12:43:00 2005-09-12 09:00:00 2005-09-12 10:00:00 Changed pyranometer and quantum sensor for calibration purposes 2008-03-06 12:39:00 2005-08-02 09:00:00 2005-08-05 10:00:00 Changed air temperature/relative humidity probe for calibration purposes 2008-03-06 12:38:00 2004-10-13 09:30:00 2005-06-05 00:00:00 Rain gage closed for season 10/13/04 at 10.30 AM DST/9.30 EST 2007-02-23 12:43:00 2004-09-28 09:15:00 2004-09-28 09:30:00 DOY 272 Battery changed. no data for 0915 or 0930 2007-02-23 12:43:00 2004-08-05 00:00:00 2004-08-05 00:00:00 Time adjusted data inserted to replace errant data(12/1/03 0:00 - 6/9/04 10:11) on 5 August 2004 2008-03-06 13:03:00 2004-06-22 00:00:00 2004-08-02 09:30:00 Rain gage found clogged; unclogged and discovered by examining the data that the problem began on 22 June 2004 2008-03-06 11:44:00 2003-12-01 09:00:00 2004-01-06 08:00:00 12V battery was not holding charge causing numerous periods of missing data; battery replaced on 6 January 2004 2008-03-06 12:37:00 2003-12-01 01:00:00 2004-06-09 10:11:00 Datalogger time found to be off by 9 hours and reset; damaged anemometer prop & tail replaced 2007-02-23 12:43:00 2003-12-01 00:00:00 2004-06-09 10:11:00 Damaged anemometer prop & tail replaced 2008-03-06 11:39:00 2003-10-14 11:30:00 2004-06-04 11:30:00 Rain Gage Covered 2007-02-23 12:43:00 2003-09-09 08:00:00 2003-09-09 08:30:00 Pyranometer and quantum sensors change for calibration purposes, wind speed bearing changed in anemometer 2008-03-06 10:47:00 2003-07-29 08:45:00 2003-07-29 09:15:00 Air temperature and RH suspended for calibration 0900 - 0915 AM (DST) 2007-02-23 12:43:00 2003-02-05 04:30:00 2003-02-05 08:30:00 Data loss 2/5/03 4.30-8.30 possibly due to low battery voltage 2007-02-23 12:43:00 2003-01-28 18:45:00 2003-01-30 10:15:00 Data loss 1/28/03 18.45-1/30/03 10.15 possibly due to low battery voltage 2007-02-23 12:43:00 2003-01-14 03:34:00 2003-01-14 09:45:00 Data loss 1/14/03 3:45-9:45 possibly due to low battery voltage 2007-02-23 12:43:00 2002-10-15 13:00:00 2003-06-03 09:00:00 Rain gage covered 10/15/02 at 1.00 p.m. EST (2 p.m. DST). 2002-10-15 00:00:00 2002-08-20 09:00:00 2002-08-20 09:30:00 Air temperature & relative humidity offline 2008-03-06 10:33:00 2002-07-24 08:30:00 2002-07-24 09:15:00 Air temperature & relative humidity offline 2008-03-06 10:31:00 2002-04-08 13:30:00 2002-06-04 00:15:00 Data lost from 4/8/02 1.30.00 - 6/4/02 12.15.00 - datalogger lost power. 2002-06-24 00:00:00 2001-10-11 10:00:00 2002-06-04 12:00:00 Rain gage covered (10:00 EST) 2001-10-11 00:00:00 2001-10-11 09:00:00 2001-10-11 12:00:00 Air temperature/relative humidity probe, quantum (PAR) sensor & pyramometer changed for calibration purposes 2008-03-06 12:29:00 2001-09-06 00:00:00 2001-09-06 00:00:00 Tipping bucket rain gage was installed to provide precipitation (non-freezing months) 2007-02-23 12:43:00 1999-07-26 09:00:00 1999-07-26 14:00:00 Station established on 3 meter tower; variables: air temperature, relative humidity, wind speed & direction, PAR, total solar irradiance 2008-03-06 12:26:00 0000-00-00 00:00:00 2013-07-15 13:30:00 Clogged rain gauge was cleared, start date of clog unknown, precipitation data needs to be nullified. This note will be updated once this is done. 2013-07-18 09:20:00 0000-00-00 00:00:00 0000-00-00 00:00:00 MME has major gaps, and, early in the record precip nulls are represented by 0s 2008-12-12 10:26:00 0000-00-00 00:00:00 0000-00-00 00:00:00 Sensors are *not* heated during the winter. 2008-01-09 14:37:00