Soil Temperature Gradients in a Northern Hardwood Forest: Soil Temperature Gradient Paired Plot Set 1 (ADC logger), 1997 to 2001
Download MetadataView Metadata in XML Format
► Metadata Provider
- Forest Ecosystem Monitoring Cooperative
- Address:
705 Spear Street
South Burlington, Vermont 05403
United States of America
Phone: (802) 391-4135
Email: femc@uvm.edu
Website: www.uvm.edu/femc
► Abstract
Long-term continuous measurements of soil temperature in a hardwood forest canopy to use in relation with other biological and physical variables within the forest.
► People
- Tim Scherbatskoy: Content Provider
- Carl Waite: Principal Investigator
- Deane Wang: Content Provider
- Joanne Cummings: Content Provider
- Miriam Pendleton: Content Provider
► Geographic Coverage
- Coordinates
► Data Table
- Title: Soil Temperature Gradient Paired Plot Set 1 (ADC logger), 1997 to 2001
- Start Date: 1997-01-01
- End Date: 2001-12-31
- Description: Measurements of soil temperature taken at 4 different depths with an ADC logger
- Purpose: Long-term continuous measurements of soil temperature in a hardwood forest canopy to use in relation with other biological and physical variables within the forest, including those at the canopy research tower at PMRC.
- Condensed Title: Z0130_SoilTempGradient_ADC_PlotSet
- Object Name: VMC.130.319
- Data Type: mySQL
- Citation: Carl Waite. 2001. Soil Temperature Gradient Paired Plot Set 1 (ADC logger), 1997 to 2001. University of Vermont. FEMC. Can be found at: https://www.uvm.edu/femc/data/archive/project/soil-temperature-gradients-northern-hardwood-forest/dataset/soil-temperature-gradient-paired-plot-set
- Online Distribution: https://vmc.w3.uvm.edu/vmcdevel/data/archive/project/soil-temperature-gradients-northern-hardwood-forest/dataset/soil-temperature-gradient-paired-plot-set
► Attribute List
- Attribute Name: DateTime
- Label: Sample date-time
- Description: Date and time of sample capture
- Storage Type: datetime
- Measurment Type: datetime
- Attribute Name: SnowFreeTemp2cm
- Label: Snow-free temperature 2cm
- Description: Temperature at 2 cm above surface of snow-free pit
- Storage Type: decimal
- Measurment Type: interval
- Standard Unit: celsuis
- Precision: 0.1
- Unit: celsuis
- Number Type: real
- Attribute Name: SnowFreeTemp-5cm
- Label: Snow-free temperature -5cm
- Description: Temperature at 5 cm below surface of snow-free pit
- Storage Type: decimal
- Measurment Type: interval
- Standard Unit: celsius
- Precision: 0.1
- Unit: celsius
- Number Type: real
- Attribute Name: SnowFreeTemp-15cm
- Label: Snow-free temperature -15cm
- Description: Temperature at 15 cm below surface of snow-free pit
- Storage Type: decimal
- Measurment Type: interval
- Standard Unit: celsius
- Precision: 0.1
- Unit: celsius
- Number Type: real
- Attribute Name: SnowFreeTemp-30cm
- Label: Snow-free temperature -30cm
- Description: Temperature at 30 cm below surface of snow-free pit
- Storage Type: decimal
- Measurment Type: interval
- Standard Unit: celsuis
- Precision: 0.1
- Unit: celsuis
- Number Type: real
- Attribute Name: SnowCoveredTemp2cm
- Label: Snow-covered temperature 2cm
- Description: Temperature at 2 cm above surface of snow-covered pit
- Storage Type: decimal
- Measurment Type: interval
- Standard Unit: celsius
- Precision: 0.1
- Unit: celsius
- Number Type: real
- Attribute Name: SnowCoveredTemp-5cm
- Label: Snow-covered temperature -5cm
- Description: Temperature at 5 cm below surface of snow-covered pit
- Storage Type: decimal
- Measurment Type: interval
- Standard Unit: celsius
- Precision: 0.1
- Unit: celsius
- Number Type: real
- Attribute Name: SnowCoveredTemp-15cm
- Label: Snow-covered temperature -15cm
- Description: Temperature at 15 cm below surface of snow-covered pit
- Storage Type: decimal
- Measurment Type: interval
- Standard Unit: celsius
- Precision: 0.1
- Unit: celsius
- Number Type: real
- Attribute Name: SnowCoveredTemp-30cm
- Label: Snow-covered temperature -30cm
- Description: Temperature at 30 cm below surface of snow-covered pit
- Storage Type: decimal
- Measurment Type: interval
- Standard Unit: celsius
- Precision: 0.1
- Unit: celsius
- Number Type: real
► Methods
- Past Methods (no longer in use)
- Plot establishment
- Started: 1993-01-13
Ended: 2013-12-31 - Method Description: Two sets of paired plots were established, each pair consisting of a plot where snow was removed after each snowfall, and a plot where snow cover was left in place
- Started: 1993-01-13
- Soil temperature measurements
- Started: 1993-01-13
Ended: 2013-12-31 - Method Description: Soil temperature measured continuously at 4 depths: 2 cm above; 5, 15 and 30 cm below soil surface.
- Instrumentation: 4-point thermocouples
- Started: 1993-01-13
- Temperature
- Started: 1993-01-13
Ended: 2013-12-31 - Method Description: 15-minute averages of temperature captured by two datalogger schemes
- Instrumentation: Campbell Scientific 21X datalogger; Analog-digital converter
- Software: Turbo Pascal
- Started: 1993-01-13
► Sampling Equipment
- Convertor Box
- Started: 1993-01-13
Ended: 2001-12-31 - Sampling Description: Analog-Digital Convertor Box wtih Turbo Pascal program on computer
- Data logger
- Started: 1993-01-13
Ended: 2001-12-31 - Sampling Description: Campbell Scientific Instruments 21X Datalogger
- Thermocouples
- Started: 1993-01-13
Ended: 2001-12-31 - Sampling Description: Custom-built thermocouples from teflon-coated 22 gauge copper-constantan wire
► Site Characteristics
- Site Description: Proctor Maple Research Center on the west slope of Mount Mansfield, on a 2% slope, adjacent to the Forest Canopy Tower, within the forest. Surrounding forest is intermediate-aged northern hardwood, with Lyman-Marlow association soil type.